型号
|
KYXS-1LF
|
KYXS-2LF
|
KYXS-3W
|
KYXS-5W
|
KYXS-8W
|
KYXS-10W
|
KYXS-15W
|
KYXS-20W
|
KYXS-25W
|
KYXS-30W
|
KYXS-40W
|
||
制冷量
|
KW
|
3.5
|
7
|
10.5
|
17.5
|
28
|
35
|
52.5
|
70
|
87.5
|
105
|
135
|
|
Kcal/h
|
3010
|
6020
|
9030
|
15050
|
24080
|
30100
|
45150
|
60200
|
75250
|
90300
|
11610
|
||
总功输入率
|
KW
|
0.94
|
1.9
|
2.7
|
4.9
|
7.3
|
9.2
|
12.8
|
18
|
22
|
27
|
35
|
|
运行电流
|
A
|
6.5
|
10
|
9
|
12.5
|
15
|
19
|
26
|
38
|
47
|
58
|
75
|
|
电源
|
单相220V 50Hz
|
三相380V 50Hz
|
|||||||||||
温控范围
|
℃
|
5~30℃(0℃以下可定制)
|
|||||||||||
温控精度
|
℃
|
±1
|
|||||||||||
冷媒
|
种类
|
|
R22(R407C/R410A)
|
||||||||||
填充量
|
KG
|
0.6
|
1.1
|
1.6
|
2.7
|
4.2
|
5.3
|
7.8
|
10.5
|
14
|
18
|
22
|
|
压缩机
|
功率
|
KW
|
0.75
|
1.5
|
2.2
|
3.75
|
6
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
冷风机
|
风压
|
pa
|
125
|
340
|
340
|
520
|
780
|
890
|
1000
|
1000
|
1000
|
1000
|
1000
|
风量
|
m³/h
|
180
|
280
|
370
|
800
|
1560
|
2300
|
3360
|
4100
|
4400
|
5400
|
6900
|
|
功率
|
KW
|
0.045
|
0.9
|
0.9
|
0.2
|
0.75
|
1.5
|
1.5
|
2.2
|
2.2
|
3
|
4
|
|
出风管径
|
|
mm
|
∅76
|
∅90
|
∅100
|
∅125
|
∅160
|
∅160
|
∅160
|
∅200
|
∅200
|
∅250
|
∅250
|
冷却水
|
水量
|
m³/h
|
0.66
|
2000
|
3000
|
5000
|
8000
|
10000
|
15000
|
20000
|
25000
|
30000
|
40000
|
管径
|
寸
|
G1/2〃
|
G1/2〃
|
G1/2〃
|
G1〃
|
G1-1/2〃
|
G1-1/2〃
|
G1-1/2〃
|
G2〃
|
G2〃
|
G2-1/2〃
|
G3〃
|
|
安全保护
|
压缩机过热保护、过流保护、高低压力保护、超温保护、相序/缺相保护,排气过热保护。
|
||||||||||||
外型尺寸
|
长
|
mm
|
680
|
790
|
930
|
1000
|
1300
|
1300
|
1550
|
1700
|
1700
|
2100
|
2100
|
宽
|
mm
|
420
|
470
|
550
|
600
|
630
|
630
|
700
|
900
|
900
|
900
|
1100
|
|
高
|
mm
|
720
|
830
|
1050
|
1180
|
1350
|
1350
|
1440
|
1480
|
1480
|
1500
|
1590
|
|
机组重量
|
KG
|
60
|
85
|
130
|
170
|
370
|
330
|
520
|
680
|
850
|
900
|
980
|
|
备注:1、以上规格参数能力的测定工况:冷却水进水温度30℃,出水温度35℃。进风温度35℃,出风温度12℃。环境干球温度35℃,湿球湿度24。 | |||||||||||||